Field Capacity & Wilting Point Set — pF Determination with Ceramic Plates 08.25.SA
pF Determination Set — overview
15 Bar Ceramic Plate Extractor
Soil

Field Capacity & Wilting Point Set — pF Determination with Ceramic Plates

A set for determining soil moisture characteristics using ceramic plates, measuring pF curves across the pF 2.0–4.2 range (0.1–15 bar suction).

This set determines soil moisture characteristics via ceramic plates, measuring pF curves in the range pF 2.0–4.2 (0.1–15 bar suction).

Working Principle

Soil moisture is removed from a soil sample by raising the air pressure in an extractor. A porous ceramic plate serves as a hydraulic link that "pushes" water out of the soil. Since the ceramic plate's pores are saturated with water, they allow water through but block air flow. As pressure increases, soil moisture equilibrates around each particle and exits through the ceramic plate and outflow tube; equilibrium is reached once no more water emerges from the outflow tube.

The method is relatively simple, applicable to prepared samples or undisturbed soil cores, and provides a reliable way of removing moisture from a sample without disturbing the soil structure. Double regulators on the pressure control panel help ensure measurement accuracy.

Set Contents

  • Two extractors (5 and 15 bar)
  • 4 ceramic plates, 1 bar
  • 4 ceramic plates, 15 bar
  • Pressure control panel
  • 20 bar compressor with reducing valve
  • 144 soil sample rings
  • Coupling hoses

Applications

  • Calculating soil pore volume and pore-size distribution
  • Calculating capillary-rise capacity
  • Calculating air and moisture content at a given groundwater level
  • Determining field capacity and available soil moisture
  • Soil suction research related to seed germination time
  • Calibrating soil moisture blocks or measurement equipment
Maximum Number of Samples48
Measuring Range1.8 – 4.2 pF
Reading Accuracy0.02 bar for <4 bar
Sample PropertyDisturbed
Packaging Size120×80×135 cm
Power SourceMains voltage
Voltage230 VAC 50Hz
📄

Operation Manual — 15 Bar Ceramic Plate Extractor

Manufacturer document (PDF, English)

Download
📄

Operation Manual — 5 Bar Ceramic Plate Extractor

Manufacturer document (PDF, English)

Download
📄

Laboratory Setup Instructions

Manufacturer document (PDF, English)

Download
🔧

Installation & Commissioning

Our expert technicians provide on-site installation and initial commissioning.

📚

User Training

We organize hands-on field training for correct and efficient use of the equipment.

🛡️

Technical Service

Our Ankara-based technical team is ready for repair, maintenance and calibration services.

📦

Spare Parts

We support you with fast supply of consumables and spare parts.